<LOGO>
FM Transmitter Measurement Report
Created: 2024-08-23 00-24-15
Measuring equipment: P75/P175/P275
http://pira.cz
Station Details
Frequency Signal Reception Station Name
94.70 MHz 5/5, 58 dBuV SANDELS
Pilot RDS Phase Difference
6.6 kHz 6.0 kHz No phase relation found.
Frequency Deviation
Limit Measuring Tolerance
75,0 kHz 1,0 kHz
MIN Hold Max. Samples at Total Samples % above 76,0 kHz
13 kHz 61 kHz 15101 6,7744
Modulation Power
Limit Measuring Tolerance
12,0 dBr 0,2 dBr
MIN AVE MAX % above 12,2 dBr
2,4 dBr 3,27 dBr 4,1 dBr 0,0
Radio Data System
PS PI PTY TP TA  MS   DI   CT 
"SANDELS " 61F1 9 (Varied) 1 0 1 9 --:--
RT
-
AF EON
92.0, 94.7, 98.5, 106.3, 107.5 MHz -
FM Scope Max at: 61 kHz MIN: 13 kHz % above 76 kHz: 6,7744 Acquired: 2024/08/23 0.23.11 Total samples: 15101 Equivalent time: 0:12:35 0 10 20 30 40 50 60 70 80 90 100 110 120 Frequency Deviation [kHz] 0 200 400
FM Scope MAX: 4,1 dBr MIN: 2,4 dBr AVE: 3,27 dBr % above 12,2 dBr: 0,0 Last value: 3,4 dBr (2024/08/23 0.23.11) 00.10 00.12 00.14 00.16 00.18 00.20 00.22 0 2 4 Pm [dBr]